var styleTmp = document.getElementsByClassName( 'toolset-blocks-styling-font-links-tmp' ); while( styleTmp[0] ) { styleTmp[0].parentNode.removeChild( styleTmp[0] ); } var scriptTmp = document.getElementsByClassName( 'toolset-blocks-script-font-tmp' ); while( scriptTmp[0] ) { scriptTmp[0].parentNode.removeChild( scriptTmp[0] ); }
MCM’s 28VDC Load Banks are designed to test 28VDC generating equipment or power source. The unit has six load steps with individual timing relays that supply up to a 1600A load. Once activated, the relays can be set to simulate a transient load comparable to an engine start. In addition, two load steps have a bypass providing a continuous load. The design provides a much more accurate simulation of aircraft loads for fully testing the power source capabilities.
Advantages & Features
- Weather resistant enclosure
- Voltage test points
- Forklift accessible
- External fan power receptacle
PART NO. | RATING | WEIGHT | DIMENSIONS L x W x H |
---|---|---|---|
DD2-5082-13 | 400A (cont.) 1600A (peak) | 125lbs. | 42”L x 26”W x 13¼H |